Hayabusa high test sigma
Potential Meterpreter/CobaltStrike Activity
Detects the use of getsystem Meterpreter/Cobalt Strike command by detecting a specific service starting
Detection Logic
{
"process_creation": {
"EventID": 4688,
"Channel": "Security"
},
"selection_img": {
"ParentProcessName
| endswith": "\\services.exe"
},
"selection_technique_1": {
"CommandLine
| contains
| all": [
"/c",
"echo",
"\\pipe\\"
],
"CommandLine
| contains": [
"cmd",
"%COMSPEC%"
]
},
"selection_technique_2": {
"CommandLine
| contains
| all": [
"rundll32",
".dll,a",
"/p:"
]
},
"filter_defender": {
"CommandLine
| contains": "MpCmdRun"
},
"condition": "process_creation and (selection_img and 1 of selection_technique_* and not 1 of filter_*)"
} False Positives
- ⚠ Commandlines containing components like cmd accidentally
- ⚠ Jobs and services started with cmd
Field Validations
Loading…
Comments (0)